Authorized Dealers

Welcome

About Tele Vue

Product List/Pics

Eyepieces

Telescopes

Filters

Mounts & Accessories

Sky Tour

Observing Accessories

Photo / Imaging

Photo / Imaging Pics

Help / Tutorials

Reviews

Owners Speak

Birding

Vixen America


© Tele Vue Optics, Inc.

 
TVFocus Software 

TVFocus Screenshot   Designed to work with Tele Vue's digital indicator kits and special RS232 cable, TVFocus is software that displays focuser position on your computer. Features include:
  • Continuous or momentary position readout
  • Up to four preset positions (saved between sessions)
    This feature is handy if you use various filters that change the point of best focus or swapping non-parfocal eyepieces
  • Yellow and green indicators when you are approaching or have achieved a preset focus position
  • Zero reset allows you to zero the indicator at any point

 

System Requirements
  • Tele Vue digital indicator and indicator to RS232 cable (images right)
  • Computer with 386, 486, Pentium or greater CPU
  • Windows 95/98/Me/NT/2000/XP or greater operating system
  • free serial port, or a USB connection and USB-to-serial adapter
Digital Indicator RS232 Cable
Digital indicator (left) and Indicator to computer RS232 cable (right)

 

Install

  • Download self-extracting archive file (2.85 MB) to a folder on your computer
  • In the download folder, run the executable to extract files to a temporary directory
  • Execute setup.exe in the temporary directory and the program will then install and register itself
  • You can delete the extracted files in the temporary directory after install

Uninstall

  • In Start/Settings/Control Panel find Add/Remove programs applet
  • Select on TVFocus and click the [Remove] button to uninstall

Instructions and Usage Tips

Digital Indicator and RS232 Cable

  • The instructions for the RS232 cable explain how to mount the cable interface in the digital indicator's battery compartment. Make sure to mount the interface with the smooth side-up (image right).
  • Mount the indicator with cable on the telescope in accordance with the instructions for the digital indicator kit.
  • Plug the serial port side of the cable into your computer's serial port or serial-to-USB adapter.
Smooth side of interface

Digital Indicator and TVFocus Software

  • A default install will place TVFocus software in Start/Programs/TVFocus on your computer. Start the software from there.
  • At the Setup tab, select the COM port connected to the RS232 cable and press the [Connect] button. If the LCD display on the indicator does not become active, you may have selected the wrong port: press [Disconnect] and try another port.
    • Troubleshooting
      You can find what COM ports are available your PC by clicking Control Panel (under Start or Start/Settings) and selecting System. Select the Hardware tab and then click [Device Manager...].   On the menu tree, expand Ports (COM & LPT). Native ports on the PC are usually COM1 and COM2. If you are using a USB-to-serial adapter, its name will show up on the list with its assigned port number.
    • If a connection can not be made with any COM port, check that the cable interfaces are tight (on the indicator the smooth side should be inserted facing up, when looking down at the LCD display).
  • Referring to the instructions that came with the digital indicator, select units of measure and set it for normal mode (usually the default mode). If you use the preset values in the Run tab (explained below), it is advisable to use the same units of measure each time you start the digital indicator.
    LCD select mm or inch
    Select mm or inches Smooth side of interface
  • The Night Vision checkbox in Setup causes the backgrounds of all applications to turn black and the text to turn deep red. This color scheme helps preserve your night-vision and is recommended for use only in the dark.
  • The Poll Time selector in Setup determines how often the display is updated. Decreasing the value here will cause the Run tab display to update faster, but may cause software on your computer to run slower. The value here will persist between sessions.

  • On the Run tab, press the [Read Continuously] button to begin reading focus positions. Turn the focuser on your scope to cause the indicator plunger to compress and expand. The large Focus Position display should update with the position of the plunger. You can return to the Setup tab to change the update rate with the Poll Time selector.
  • Pressing any of the four Set buttons in the Run tab will save the current focus position and highlight the associated position box in green. You can enter a reminder note in the text box to the right of the set focus position. You can enter text past the visible width of the box. These preset positions and notes are saved for the next time you start the program. For the presets to have meaning in the next session, you must set the digital indicator to the same units of measure.
  • The Display Offset checkbox and [Set Zero] button in the Run tab work together to create a virtual zero point. Clicking [Set Zero] makes the current focus position a virtual zero point. Checking the Display Offset checkbox causes the Focus Position to display the offset position from the virtual zero point. It will also change the values in the preset boxes to reflect the offset distance from the virtual zero point to the preset focus points. In this mode, the reading on the digital indicator will differ from that of the Focus Position display. Uncheck the Display Offset checkbox to return to the initial zero point.

Product List & Code
Imaging System Accessories
RSC-2320 Indicator to computer RS232 cable 10 ft.
RMK-2002 10 Micron Indicator Kit for 2" focuser
RMF-2003 1 Micron Fine Indicator Kit for 2" focuser
LMK-2404 10 Micron Indicator Kit for 2.4" focuser
LMF-2405 1 Micron Fine Indicator Kit for 2.4" focuser
RMK-2060 10 Micron Indicator Kit for TV60is
RMF-2061 1 Micron Fine Indicator Kit for TV60is


Featured Dealers

Adorama Camera New York, NY
Phone1-800-223-25001-212-741-0052 E-mailmichaelp@adorama.com
Astronomics Norman, OK
Phone1-800-422-78761-405-364-0858 E-mailquestions@astronomics.com
Phone1-212-502-62361-800-336-7916 E-mailphoto@bhphotovideo.com
High Point Scientific Montague, NJ
Phone1-800-266-95901-973-293-7200 E-mailinfo@highpointscientific.com
OPT Telescopes Oceanside, CA
Phone1-800-483-62871-760-722-3343 E-mailopt@optcorp.com
Telescopes.com Omaha, NE
Phone1-800-303-5873 E-mailinfo@telescopes.com

See all Tele Vue dealers

See this section on our new website.


Best Viewed at
 1024x768

Print Page

For information call between 9 a.m. and 5 p.m. ET Monday through Friday:  845 469 4551
Copyright © 2003-2010 Tele Vue Optics, Inc., 32 Elkay Dr., Chester, NY 10918. All rights reserved.